BMS Agent

Catch the failure before the alarm.

Inspectr continuously reads BMS trends, alarms, and work order history — clearing false positives, verifying real faults, and catching developing issues before an alarm fires. What matters becomes an action, ready to review or dispatch.

01

Clear the noise

Every alarm and open issue is checked against point history, schedules, related signals, and prior work. False positives are cleared with the reasoning logged, leaving the team with what actually needs attention.

02

Verify & cost

Real faults are checked against runtime, meter data, and operating conditions, then quantified. What's wrong, why Inspectr believes it, and what it's costing are attached to the finding.

03

Predict & act

Inspectr watches for changes that haven't crossed an alarm threshold yet — fan speed creep, control drift, abnormal cycling, degrading performance. Developing faults are caught early and turned into a remote fix or dispatch-ready work order.

AHU Supply Fan — Failure Predicted

Before — what the BMS showed

No alarm has fired. Every point is within limits. Supply fan speed has crept from 62% → 68% over six weeks to maintain the same duct static.

After — Inspectr prediction

  1. 01

    Trend flagged+6% fan speed for the same static pressure, invisible to existing alarm thresholds.

    Source: BMS point history, six-week trend

  2. 02

    Pattern matchedThe same creep preceded belt failure in prior work order history.

    Source: work order history + pattern memory

  3. 03

    Likely cause rankedBelt wear or filter loading identified as the likely cause, weeks before failure.

    Source: asset record + O&M specs

  4. 04

    Action draftedWork order ready before the equipment breaks — operator approves, CMMS dispatches.

No alarm. No ticket. Caught in the trend.

What you get

Continuous review of BMS trends, alarms, and work order history
Alarm triage with false positives cleared and reasoning logged
Real faults verified against runtime, meter, and operating data
Estimated impact attached to confirmed faults
Developing issues caught before existing alarms fire
Remote fixes or dispatch-ready work orders for every actionable finding
Every action routed through your Activity Center and existing CMMS workflow

Replaces

Alarm floods nobody has time to triage, engineers manually piecing together trends, predictive scores that stop at a dashboard, and failures that only become obvious when equipment stops.

Who it's for

Engineering & reliability leadsROC / analytics teamsAccount engineers

Every cleared alarm, confirmed fault, and resolved issue sharpens what Inspectr catches next — earlier, with better evidence behind it.